        1. Photovoltaic Auto safety comprehensive tester

          Product Description:Name:Photovoltaic Auto safety comprehensive testerType:BND-CS9933EG-15Standards: IEC61730; IEC61215; IEC 61646Description of PV safety tester:Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.
          Description

          Product Description:

          Name:Photovoltaic Auto safety comprehensive tester

          Type:BND-CS9933EG-15

          Standards: IEC61730; IEC61215; IEC 61646


          Description of PV safety tester:

          Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.

          According to the IEC61730 standard(photovoltaic module safety qualification—part I: Requirements for construction which describes the fundamental construction requirements for photovoltaic modules in order to provide safe electrical and mechanical operation during their expected lifetime), the definition of PV module application is divided into A, B, C.

          The current measuring terminal can choose the grounding mode or the floating mode. Insulation voltage withstand test of photovoltaic module is based on the application of IEC61215/61646 and the maximum voltage of the system.

          Maximum test voltage for the application class A:2000V plus 4 times the maximum system voltage

          For the maximum voltage application category B:1000V system 2 times

          According to the calculation of a maximum voltage of 8000V, CS9923GS, CS9923G is based on this standard production

          According to the calculation of the maximum voltage B 6000V, CS9922G, CS9922GS is based on this standard production


          Performance characteristics:

          ◆With safety anti-electric wall function, it can automatically detect whether the input power is correct

          ◆For photovoltaic system panels, controllers, and battery packs

          ◆After the DC withstand voltage and insulation resistance tests are completed, the tester can quickly discharge within 0.2 seconds to protect the safety of the operator

          ◆With current lower limit alarm function, it can prevent the open circuit of the test line from causing misjudgment of the tested components during the test. The output voltage has voltage upper limit and voltage lower limit alarm functions

          ◆With keyboard lock function to prevent the operator from modifying the test parameters and ensure that the tested object is tested according to the set parameters

          ◆Linear power amplifier drives the output of sinusoidal voltage (current), and the crest factor is within the range of 1.3 to 1.5

          ◆Adopts 240*64 graphic LCD display and humanized interface design

          ◆With Chinese and English display interfaces, it can meet the different needs of different users.

          ◆Test parameters can be saved in advance: 30 files can be set, and each file can have 99 test steps

          ◆Optional RS232, RS485, USB interface, standard PLC interface

          pv-auto-safety-tester (1).jpg


          The Specification of the PV safety test system:

          Model

          BND-CS9933EG-15









          ACW


          The output voltage

          Range

          0.050kV~6.500kV

          Accuracy

          ±(1.5% reading + 5V)

          Resolution

          1V

          Maximum output power

          130VA(6.500kV/20mA)

          Maximum rated current

          20mA

          Lower current range

          0~20mA, 0=no lower limit

          Current range

          200uA, 2mA, 20mA

          Output waveform

          Sine wave

          Output waveform distortion

          ≤2% (no load or pure resistive load)

          Crest factor

          1.3~1.5

          Output signal type

          DDS+ amplifier

          Voltage rise time

          0.3s~999.9s 0=voltage rise time off

          Test time

          0.3s~999.9s 0=continuous test

          Voltage fall time

          0.3s~999.9s 0=voltage fall time off

          Interval time

          0.0s~999.9s 0=interval time off

          Output voltage mode

          N-mode, G-mode







          DCW






          The output voltage

          Range

          0.050kV~6.500kV

          Accuracy

          ±(1.5%Value +5V)

          Resolution

          1V

          Maximum output power

          65W(6.500kV/10mA)

          Maximum rated current

          10mA

          Current range

          2uA、20uA、200uA、2mA、10mA

          Ripple factor

          ≤5%

          Discharge time

          ≤200ms

          Maximum charge current

          10mA

          Voltage rise time

          0.3s~999.9s 0=voltage rise time off

          Test time

          0.3s~999.9s 0=continuous test

          Voltage drop time

          0.3s~999.9s 0=voltage drop time off

          Interval time

          0.0s~999.9s 0=interval time off

          Delay alarm time

          0.3s~999.9s 0=delay alarm time off

          Output voltage mode

          N mode, G mode


          IR



          The output voltage

          Range

          0.050kV~1.500kV

          Accuracy

          ±(1.5% reading +5V)

          Resolution

          1V

          Maximum upper limit setting value

          50.00GΩ




          Maximum and minimum setting values

          50.00GΩ

          Minimum setting values

          1MΩ

          Voltage rise time

          0.3~999.9s 0=voltage rise time off

          Test time

          0.3s~999.9s 0=continuous test

          Interval time

          0.0s~999.9s 0=interval time off

          Automatic gear switching

          Can be set to on or off

          Discharge time

          ≤200ms







          GR


          Output current

          Range

          3.00A~52.00A(DC)

          Accuracy

          ±(1.5% Value +0.2A)

          Resolution

          0.01A

          Maximum output power

          250W(50A/0.10Ω)

          Maximum output current

          50AW

          Resistance upper limit setting value

          40A x150mW

          Set current value

          Output waveform

          Sine wave

          Output waveform distortion

          ≤2% (no load or pure resistive load)

          Crest factor

          1.3~1.5

          Output signal type

          DDS+power amplifier

          Test time

          0.3s~999.9s 0=continuous test

          Interval time

          0.3s~999.9s 0=interval time off

          Voltmeter


          Range

          0.050kV~6.500kV

          0.050kV~6.500kV

          0.050kV~6.500kV

          0.050kV~6.500kV

          Accuracy

          ±(1.5% reading +5V)

          Resolution

          1V

          Display value

          RMS value



          Withstand voltage ammeter

          Measure range

          AC

          0 ~ 20mA

          DC

          0 ~ 10mA


          Resolution

          AC

          200uA: 0.1uA, 2mA: 1uA, 20mA: 10uA

          DC

          2uA: 0.001uA, 20uA: 0.01uA, 200uA: 0.1uA, 2mA: 1uA,

          10mA: 10uA

          Measurement accuracy

          ≥2mA: ±(1.5%+5 digits), <2mA: ±(2%+5 digits)

          Offset function

          The current of the test leads and accessories can be subtracted.

          Test mode

          GND mode: RETURN terminal connected to the chassis

          FLOAT mode: RETURN terminal not connected to the chassis


          Measurement range

          1MΩ~50000MΩ


          Resolution

          1MΩ~9.999MΩ:0.001MΩ,10MΩ~99.99MΩ:0.01MΩ,

          100MΩ~999.9MΩ:0.1MΩ,1000MΩ~9999MΩ:1MΩ

          10GΩ~50GΩ:10MΩ

          Insulation resistance meter



          Accuracy

          0.100kV~0.200kV:1MΩ~999MΩ ±5%,1000MΩ~3000MΩ ±10%

          0.201kV~0.499kV:1MΩ~999MΩ ±5%,1000MΩ~5000MΩ ±10%

          0.500kV~1.000kV:1MΩ~999MΩ ±5%,1000MΩ~9999MΩ ±10%

          10000MΩ~50000MΩ ±15%

          Ground current meter

          Measuring range

          3.00A~52.00A

          Resolution

          0.01A

          Accuracy

          ±(1.5% of reading + 0.2A)

          Display value

          RMS value

          Ground resistance meter

          Range

          0~510mΩ

          Accuracy

          When the current is less than 5.00A, it is ± (3% of reading + 3mΩ) When the current is ≥ 5.00A, it is ± (2% of reading + 2mΩ)

          Resolution

          0.1mΩ

          Measuring method

          Four-terminal method

          Timer

          Range

          0~999.9s

          Resolution

          0.1s

          Accuracy

          ±(0.1%+50ms)