        1. ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

          Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
          Description

          Product Description:

          Name:ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

          Type:ORP10

          Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.

          ■ ORP measurement

          ■ Output Interface with RS485, Voltage, Current

          ■ High accuracy with excellent stability

          ■ Reverse power protection and Built-in TVS/ESD protection


          Specifications


          Output Interface

          Analog Voltage 0-2V        

          (Output resistance ~0ohm)

          Analog Current 4-20mA        

          (Load Resistor<500ohm)

          RS485        

          Modbus-RTU

          Power Supply

          3.9-30V/DC

          12-30V/DC

          3.9-30V/DC

          Power Consumption

          10mA@24V DC

          30mA@24V DC        

          (with 20mA output signal)

          10mA@24V DC

          ORP Measurement

          Range:+/-2000mV,Resolution:1mV,Accuracy:±2%

          IP Ratings

          Electrode:IP68        

          Transmitter:IP65

          Operating Temperature

          -40~85℃

          Installation

          Electrode:3/4″NPT screw threads        

          Transmitter:Mounting hole

          Cable Length

          Power and Signal Cable:2 meters or Customize        

          Electrode Cable:5 meters

          Dimension

          Electrode:3/4″NPT screw threads        

          Transmitter:128*70*42mm



          Parameters

          Code

          Comments

          Code 1:        

          Product Series

          ORP10

          ORP10 transmitter

          Code 2:        

          Power Supply

          A        

          B

          3.9-30V DC        

          3.3-16V

          Code 3:        

          ORP Range

          A        

          B

          C

          +/-2000mV        

          +/-1000mV

          Customize

          Code 4:        

          Output Interface

          A        

          B

          C

          D

          E

          F

          G

          Analog Voltage 0-2V        

          Analog Current 4-20mA

          RS485,Modbus-RTU

          RS485,Modbus-RTU & Analog Voltage 0-2V

          RS485,Modbus-RTU & Analog Current 4-20mA

          SDI-12

          Customize

          Code 5:        

          Cable Length

          002        

          XXX

          Electrode Cable:5 meters , Power and Signal Cable:2 meters        

          Electrode Cable:5 meters , Power and Signal Cable:xxx meters

          Ordering Code Example:

          ORP10 transmitter Power Supply 3.9-30V DC, ORP Range +/-2000mV, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ORP10 – A A C 005