        1. UL 94 Horizontal and vertical flame test apparatus BND-SPR

          The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
          Description

          Product Description:

          Name:UL 94 Horizontal and vertical flame test apparatus

          Type:BND-SPR


          The Basic introduction of the flame tester:

          1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

          2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


          Technical Parameter of flame test:

          Model

          BND-SPR   Horizontal vertical flame tester

          Kinds

           500W(5V class )

           50W(HB/V class)

          Test Flame

          500W(burning test for V-0,V-1,V-2  classification)

          50W(burning test for V-0,V-1,V-2 classification)

          Burner Tube

          Internal diameter: Φ 9.5mm±0.3mm

          Internal diameter: Φ 9.5mm±0.3mm, 

          Burning Angle

          0°,20°,45°

          0°,20°,45°

          Thermocouple

          Type K (Ni/Cr - Ni/Al)

          Type K (Ni/Cr - Ni/Al)

          Thermocouple Size 

          0.5 mm

          0.5 mm

          Standard Copper Block 

          9mm±0.01mm,

          weight:10g±0.05g before drilling.  

          5.5mm±0.01mm,

          weight:76g±0.01g before drilling.

          Time for Temperature to Increase

          From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

          From 100°C±5°C to 700°C±3°C;

          44s±2s (preset)

          Gas Flow

          965±32ml/min

          105±10ml/min

          Gas Supply

          methane,min.98% purity

          methane,min.98% purity

          water-column 

          125m±5mm

          ‹10mm

          Test  Time

          54±2s

          44±2s

          Flame Height Indicator

          40±1mm

          20±1mm

          Volume Of Chamber

          >0.5m³, black interior

          >0.5m³, black interior

          Conform to standard

          UL94,IEC60695-11-3,IEC60695-11-20

          UL94,IEC60695-11-4,IEC60695-11-10