        1. Weather Meteorological Monitoring Station

          Daisy10 multi-parameter meteorological monitoring station is a multi-element automatic observation station. It can monitor conventional meteorological elements such as temperature, humidity, air pressure, wind direction, wind speed, soil temperature and humidity, and is widely used in meteorology, environmental protection, airports, agriculture and forestry, hydrology, military, storage, scientific research and other fields.
          Description

          Product Description:

          Name:Weather Meteorological Monitoring Station

          Type:Daisy10


          1. Application:

          Daisy10 multi-parameter meteorological monitoring station is a multi-element automatic observation station. It can monitor conventional meteorological elements such as temperature, humidity, air pressure, wind direction, wind speed, soil temperature and humidity, and is widely used in meteorology, environmental protection, airports, agriculture and forestry, hydrology, military, storage, scientific research and other fields.

          1) A variety of parameters are measured in one, the optional parameters include: air temperature, air humidity, dew point, atmospheric pressure, light intensity, carbon dioxide, soil moisture, soil temperature, soil conductivity, soil PH value, and leaf temperature, leaf humidity, Wind speed, wind direction, solar radiation, etc.

          2) The sensor has high accuracy, fast response, good interchangeability and reliable performance.

          3) DC wide range power supply, RS485 interface, standard Modbus protocol

          4) Multi-parameter integration, easy for system integration.

          5) Perfect protection circuit.


          2. Technical parameters:

          Signal output type

          RS485 interface

          Modbus protocol

          Supply voltage

          9-30V / DC DC

          Preheat time

          3 minutes

          Response time

          30 seconds (90%)

          Static power

          20mA @ 24V DC

          Operating environment

          Working temperature: -40 ~ 80 ℃

          Working humidity: 0 ~ 95% RH (no condensation)

          Installation method

          Bracket installation (with bracket mounting plate)

          Default cable length

          Power supply and communication cable: 2 meters, cable length can be customized.

          Connection method

          Wiring installation

          Dimensions

          Diameter * height = 140 * 300mm

          Air temperature

          Range: -40 ~ 80 ℃

          Accuracy: +/- 0.3 ℃

          Resolution: 0.01 ℃

          Air humidity

          Range: 0 ~ 100%

          Accuracy: +/- 4%

          Resolution: 0.01%

          Dew point

          Range: -40 ~ 80 ℃

          Accuracy: +/- 0.5 ℃

          Resolution: 0.01 ℃

          Air pressure

          Range: 300 ~ 1100mbar

          Accuracy: +/- 1mbar

          Resolution: 0.1mbar

          Illumination

          Range: 0 ~ 200,000 Lux

          Accuracy: +/- 5%

          Resolution: 0.1Lux

          carbon dioxide

          Range: 0 ~ 5000ppm

          Accuracy: +/- (50ppm + 5% reading value)

          Resolution: 1ppm

          Soil temperature

          Range: -40 ~ 80 ℃

          Accuracy: +/- 0.5 ℃

          Resolution: 0.01 ℃

          Soil Moisture

          Range: 0 ~ 100%

          Accuracy: 2% within 0-50%, 3% within 50-100%

          Resolution: 0.01%

          Soil conductivity

          Range: 0 ~ 20000us / cm

          Accuracy is +/- 3% in the range of 0 ~ 10000us / cm; +/- 5% in the range of 10000 ~ 20000us / cm

          Resolution: 1us / cm

          Leaf temperature

          Range: -40 ~ 80 ℃

          Accuracy: +/- 0.5 ℃

          Resolution: 0.01 ℃

          Foliar humidity

          Range: 0 ~ 100%

          Accuracy: +/- 5%

          Resolution: 0.01%

          Soil pH

          Range: 0 ~ 14PH

          Accuracy: +/- 0.1PH

          Resolution: 0.01PH

           

          3. Dimension:

          Diameter: 140mm, height: 300mm


          4. Model selection:


          Code number

          code

          Code description

          Code 1: Product series

          Daisy10

          Daisy10 multi-parameter weather monitoring station

          Code 2: Supply voltage

          A

          9-30V DC

          Code 3: Output signal

          A

          RS485 interface, Modbus protocol

          Code 4: Communication and power cable length

          002

          XXX

          2 meters long

          Customized, XXX is any line length (unit: m)

          Code 5: Installation method

          A

          X

          Bracket installation

          This item is not needed

          Code 6: Air temperature

          A

          X

          Range: -40 ~ 80 ℃

          This item is not needed

          Code 7: Air humidity

          A

          X

          Range: 0 ~ 100%

          This item is not needed

          Code 8: Dew point

          A

          X

          Range: -40 ~ 80 ℃

          This item is not needed

          Code 9: Atmospheric pressure

          A

          X

          Range: 300 ~ 1100mbar

          This item is not needed

          Code 10: Illumination

          A

          X

          Range: 0 ~ 200,000 Lux

          This item is not needed

          Code 11: Carbon dioxide

          A

          B

          C

          D

          E

          F

          X

          Range: 0-1000ppm

          Range: 0-2000ppm

          Range: 0-5000ppm

          Range: 0-10000ppm

          Range: 0-30000ppm

          Range: 0-50000ppm

          This item is not needed

          Code 12: Soil temperature

          A

          X

          Z

          Range: -40 ~ 80 ℃

          This item is not needed

          Customized (parameters such as cable length)

          (Default 2 meters long)

          A

          X

          Z

          Range: 0 ~ 100%

          This item is not needed

          Customized (parameters such as cable length)

          Code 13: Soil moisture

          A

          X

          Z

          Range: 0 ~ 20000us / cm

          This item is not needed

          Customized (parameters such as cable length)

          (Default 2 meters long)

          A

          X

          Z

          Range: -40 ~ 80 ℃

          This item is not needed

          Customized (parameters such as cable length)

          Code 14: Soil conductivity

          A

          X

          Z

          Range: 0 ~ 100%

          This item is not needed

          Customized (parameters such as cable length)

          (Default 2 meters long)

          A

          X

          Z

          Range: 0 ~ 14PH

          This item is not needed

          Customized (parameters such as cable length)

          Model example:

          Daisy10 multi-parameter weather monitoring station, 9-30V DC power supply, RS485 interface, Modbus protocol, power supply and communication cable 2 meters, bracket installation, air temperature, air humidity, dew point, atmospheric pressure measurement The selection code is: Daisy10-AA002AAAAAXXXXXXXX